Low Loss Cable Assemblies
Compression resistant low loss, low density dielectric
Low insertion loss and excellent amplitude stability
Less prone to damage during handling and installation
Quadraform shielding
Longer cable assembly life due to greater connector retention
Laminate construction provides low signal leakage
Highly reliable soldered connections
Various standard connector options and a number of ready-to-ship standard assemblies
Reduced lead time for configured assemblies
Cost-effective, same-day shipment options for standard configurations
True Blue® 125
True Blue® 205
True Blue® 290
True Blue® 420
Cable Designator
90
Diameter (plain cable, in/mm)
0.125 / 3.18
0.204/5.18
0.286/7.26
0.414/10.52
Operating Frequency (Max, GHz)
50.0
26.5
18.0
12.0
Attenuation–Nominal @ 2 GHz (dB/ft)
0.231
0.110
0.078
0.054
Attenuation–Nominal @ 10 GHz (dB/ft)
0.532
0.259
0.185
0.131
Attenuation–Nominal @ 18 GHz (dB/ft)
0.725
0.357
0.257
–
Attenuation–Nominal @ 26.5 GHz (dB/ft)
0.892
0.444
Attenuation–Nominal @ 50 GHz (dB/ft)
1.262
Power Handling–Avg.(watts @ 1 GHz)
280
750
1400
1700
Phase Stability vs. Temperature(ppm, nominal)
3300
1625
1950
1500
Phase Stability vs. Flex*(degrees @ 18 GHz, nominal)
3.50
8.1
4.50
3.50†
Amplitude Stability vs. Flexure* (dB @ 18 GHz, nominal)
0.01
0.01†
Minimum Bend Radius (in/mm)
DYNAMIC
1.25 / 31.75
2.10 / 53.34
2.90 / 73.66
4.00 / 101.60
STATIC
0.50 / 12.70
1.00 / 25.40
1.50 / 38.10
2.50 / 63.50
Shielding Effectiveness–Minimum(dB @ 1 GHz)
85
105
100
Weight (grams/ft & /m)
8.00 / 26.25
20.00 / 65.62
36.00 / 118.11
79 / 259.12
Operating Temperature Range (°C)
–55 to +110
–55 to +150
2" / 50.80 mm mandrel
4.5" / 114.30 mm mandrel
8" / 203.20 mm mandrel